Central and North-East/Yorkshire Branch Hosts

A hybrid event on Domestic Air Source Heat Pumps: Towards Guidelines for Modelling and Measurement

Domestic Air Source Heat Pumps: Towards Guidelines for Modelling and Measurement

Date: 03-12-26
Time: 18:00
Location:

This is a hybrid event with in person and zoom options available. 

Register your attendance via CPDTag - Zoom details will be shared to those registered: https://www.cpdtag.com/app.php?event=FB891F825F4E5AB9FB6AAC4D56F763F

Location: IOA HQ, 406 Silbury Blvd, Milton Keynes MK9 2AF


 

Live streaming available: Yes

About the Talk
The IOA / CIEH Domestic Air Source Heat Pumps Professional Advice Note (2026) allows a Suitably Qualified Acoustician to demonstrate cmpliance with the 37 dB(A) criterion through "appropriate sound propagation modelling", where an installation narrowly fails the MCS 020a calculation. Planning conditions may also require the sound from an installed unit to be measured. There is not yet an agreed way of doing either. This talk presents two proposals as a starting point for agreeing shared guidance, and invites interest for people to be part of the development group.

Modelling
Based on thousands of calculations in CadnaA, from theoretical cases and real sites , we propose a series of aspects that we think should be included in guidelines: hard ground with the clause 7.3.1 method a point source at the geometric centre of the unit for typical distances, and when a box source is needed instead; when single-figure data is sufficient; receivers placed on the façade to give the free-field incident level and avoid the step changes created by reflection thresholds; at least three orders of reflection, with ray paths checked.
We also show some pitfalls - how the way a building is drawn can switch a reflection on or off, and why a boundary fence below the line of sight still matters.

Measurement
Over 1,200 hours of monitoring at eight installations shows that modern units rarely have a single sound level. We found three operational profiles - unimodal, bimodal (with step changes of 8-12 dB below a site-specific temperature) and continuously variable (around 1 dB per degree as temperature falls).
We propose a protocol. A complementary narrative interview protocol is proposed for where resident experience is in question. The question of how to assess sound over a whole heating season remains open.
There will be plenty of time for discussion. Is the highest daily LAeq,1hr at 7 °C the right measure? Do we need a seasonal sound level? What should modelling and measurement guidelines prioritise? The views from the meeting are intended to help shape the next steps in developing practitioner guidance, as well as encourage people to join the development group.

The work was carried out at Apex Acoustics as part of the project "Reducing the barriers to ASHP installations", funded by Nesta and the MCS Foundation. https://apexacoustics.co.uk/news/reducing-the-barriers-to-ashp-installations

About the Speaker
Jack Harvie-Clark founded Apex Acoustics in 2006, now a 100% employee-owned consultancy, after a First in Engineering at Cambridge specialising in thermodynamics and fluid mechanics. Alongside commercial work he has researched and published since 2012, with interests including noise, ventilation and overheating in residential design, soundscape, and noise from ASHPs. He sits on the drafting panels for BS 8233 and BS 7445, chairs the IOA NE & Yorkshire Branch, and chaired the ANC from 2016 to 2018.